Six hundred twenty gas engines. That's what one Texas air permit now allows at a single OpenAI campus.

That isn't a backup generator, that's a utility with a fence around it.

Welcome to The Data Center Daily. It's Saturday, November 21st, I'm Sarah, and Matt's here too. On today's list: Texas approving gas plants again, the IEA's new world outlook on data center power, Meta stepping back from its 2030 net-zero date, and PJM's transmission bill getting bigger, with data center construction named as one of the reasons.

If today's show was useful, follow us wherever you're listening — the next one will be waiting.

Michael Thomas, writing in the Cleanview newsletter:

The plant will power Stargate Frontier, the campus Vantage Data Centers is building for OpenAI in Shackelford County. The permit allows 620 gas engines with 2,582 MW of capacity.

On Wednesday the 18th we covered Texas regulators resuming data center environmental permits. This is what came out the other end. VoltaGrid got the permit on Thursday the 19th. It replaces VoltaGrid's first permit, which covered 210 engines and 709 megawatts, less than half of what the campus needs. Cleanview says that makes Frontier the largest gas engine-powered data center with a permit in its tracker. Only a few on-site plants are bigger, including Amazon's GW Ranch and Fermi America's Project Matador, both also in Texas.

And this wasn't the only one. Cleanview counts about 5 gigawatts of new on-site gas approved for data centers since permitting restarted earlier in the week. That brings Texas to roughly 26 gigawatts of permitted on-site gas. Twenty-six gigawatts, behind the fence, permitted.

The money side moved on Friday. Reuters reports Oracle said its infrastructure contract with OpenAI is fully funded after a final capital raise. That's the 20 billion dollars it announced earlier this month, about half stock and half debt. In a post on X, Oracle said the financing it outlined at its investor day, including vendor financing, is in place, and that the Shackelford County campus is fully permitted. It also said handover of Nvidia's Vera Rubin racks there is on track for the coming weeks. The shares rose as much as 3.3 percent after hours.

Fully funded, with ten billion of it borrowed. I'll take the word funded. I'm not ready to call it de-risked. Abilene is nearly complete, per Oracle, and the two of them plan 4.5 gigawatts more in the US on top of it. That's a lot of steel to hang on one tenant.

Then there's the political clock. Governor-elect Gina Hinojosa campaigned on pausing all data center permits. In a Fox News interview on Thursday, she said she doesn't have the power to stop data centers that already hold permits. Cleanview estimates another 4 to 8 gigawatts could be approved before she takes office on January 19th. Where that range lands depends on December 16th, when the state's environmental commissioners vote on hearing requests against Chevron's Kilby plant for Microsoft.

So it's a land rush with a deadline. Get the permit before inauguration and you're grandfathered. That's not a planning process, that's musical chairs.

Camilla Naschert at S&P Global, on the International Energy Agency's annual outlook:

This trajectory is already straining power grids, upending supply chains and triggering a wave of new gas generation contracts that could lock in higher emissions for decades, the agency said in its World Energy Outlook 2026 report.

The World Energy Outlook came out Thursday. The headline numbers: data center electricity use grew 17 percent in 2025, investment hit 565 billion dollars, and the IEA expects another 4 trillion dollars of data center-related spending by 2030. In its Stated Policies Scenario, consumption doubles to about 1,000 terawatt-hours by 2030, with AI-optimized capacity driving around three-quarters of that growth.

The new part is the satellites. The IEA is watching 93 large purpose-built AI factories from orbit. Their inferred capacity grew tenfold in 24 months, to 17 gigawatts as of September, and they're headed for about 50 gigawatts once they're finished. For scale, the IEA puts all data centers worldwide at 120 gigawatts today.

It ties straight back to Texas. As of August, the IEA counted about 180 gigawatts of gas-fired capacity planned in the US to supply data centers directly, plus 11 in Canada and 4 everywhere else. But because of the turbine backlog, it expects most of that not to come online until the 2030s. Coal and gas supply about 60 percent of the electricity data centers use today, and the agency projects the sector's emissions rising 70 percent by 2030.

Hundred and eighty gigawatts planned, and most of it waiting on turbines nobody can deliver. Planned is doing a lot of work in that sentence. Which is why a permit for 620 engines in Texas is worth more than a slide with a gigawatt on it.

Two findings will get quoted in rate cases. First, the IEA says its analysis doesn't yet show a clear link between data center growth and higher electricity prices. Bills can rise where a facility needs dedicated network or generation investment, and pressure can ease where it uses spare capacity and pays its share of fixed costs. Second, US states adopted nearly five times as many data center moratoria in the first seven months of 2026 as in all of 2025.

Both sides will grab the first one. Ratepayer advocates read it as no clear link yet. Developers will drop the yet. The second one is the real constraint. Grid queues are measured in years in Denmark, Finland, Northern Virginia and Texas, where prospective data center capacity already far exceeds peak load. And Norway's regulators have paused new data center connection applications.

Jeremy Hsu, writing in Ars Technica:

“We are re-evaluating our timelines, sequencing, and interim milestones—including the 2030 timeframe for our net zero emissions goal and our near-term intensity targets—so our approach reflects current operating realities while keeping progress transparent year over year,” Peterson and Swedeen wrote in the report.

That's Rachel Peterson, Meta's vice president of data centers, and Blair Swedeen, its global head of net zero and sustainability, in the 2026 sustainability report Meta published on November 19th. They put it down to AI infrastructure demand growing, quote, faster than almost anyone projected. Ars notes that Amazon, Google and Microsoft have all stuck with their original goals so far.

Look at the numbers and you can see why. Total emissions went from 15.6 million metric tonnes in 2024 to more than 21.7 million in 2025. That's nearly 40 percent, the biggest year-over-year jump any of the four big US tech companies reported. Microsoft was up 25, Google 18, Amazon 16. Even after renewables and carbon removal, Meta's net emissions rose 45 percent, from about 8.1 to 11.8 million tonnes.

Meta attributes much of the increase to capital goods, meaning things like the servers, not just the electricity. To be fair to Meta, Ars says it likely still has one of the smallest total footprints among the big tech companies.

The water numbers are where I'd look. Water used at its own facilities went down, from 825 million gallons to 790 million. But use in water-stressed areas rose from 198 to 246 million. And water tied to the electricity it buys went from 19 billion gallons to more than 26 billion. So the cooling loop saves water, and the power plant spends it thirty times over.

Meta gets some credit for disclosing it. Ars cites Data Center Dynamics: Meta is the only hyperscaler that reports indirect water use. That matters more as closed-loop cooling cuts water use on site but adds electricity. It also fits the IEA's numbers, which tie nearly 40 percent of data center water use to power generation.

Here's my question for every infrastructure lead listening. If the first hyperscaler has moved its date, how long do the other three hold? Every gas engine we just talked about makes that a harder promise to keep.

Ed Moltzen, writing for American Buildout:

PJM’s board approved a net $3.51 billion increase for previously approved transmission projects. Projects that cite labor among several reasons for higher costs account for about $3.17 billion of that increase, based on PJM’s figures.

The board approved these revisions on November 17th, and they come from a November staff white paper. PJM lists competition for labor, materials, manufacturing capacity and specialized resources from rapidly expanding data center construction as one cause. The others are electrification, grid modernization and renewable interconnections. Two project groups that name data center construction explicitly add up to about 682 million dollars, around 19 percent of the total.

The biggest piece is Valley Link Transmission. Its three projects went from 2.732 billion in 2024 dollars to 5.115 billion in 2026 dollars, and that's 2.38 billion of the increase, roughly 68 percent. The in-service date slipped from June 1st, 2029, to May 31st, 2031. Two more years of waiting on wires.

Then there are the single-line items. BGE's portion of the Bramah to High Ridge 500 kV line roughly doubled, from 407 million to 810 million. A reconductoring job, Conastone to Northwest Number 2, went from about 38 million to 136 million, around a 260 percent increase.

And now my favorite question: who pays? Under Schedule 12 of PJM's tariff, baseline transmission costs go to responsible customers, which means load in those zones. PJM says it will file the cost allocations at FERC within 30 days. For most BGE and PEPCO projects, cost-containment provisions are supposed to soften the hit. Supposed to.

The contractor data says the same thing. In an AGC survey, 58 percent of firms doing data center work said data centers increased competition for skilled workers, and 85 percent of data center contractors with electrician openings had trouble filling them. Separately, CNBC's Diana Olick reports Turner and Townsend's new survey has US data center construction costs up 13 percent year over year, more than twice the global rate. Its North America lead, Paul Barry, expects increases of 6 to 10 percent next year.

So the same electricians are wiring the data hall and the substation feeding it, and the grid side pays the bid-up rate. I'm with the line crews on this one. Those apprenticeships take three to four years, and there's no shortcut.

If Meta's emissions report has you thinking about the bigger questions around this stuff, our sister show AI Safety Daily covers AI alignment, model evaluations, emerging risks and governance.

It runs on weekdays and focuses on what changed, what the evidence says, and why it matters. Look for AI Safety Daily wherever you found us.

One loose end. Last time we said we'd have Southwest Power Pool's show-cause filing. Fracmoo reported it hadn't appeared on FERC's docket as of early Friday, so it's at the top of the list for Monday.

So is PJM's answer to the seven state advocates, which they asked for in writing by Monday, November 23rd. That's when we're back. The Data Center Daily is a Lantern Podcast. Enjoy the rest of your weekend.